Question 1 of 10
1. Question
During your tenure as operations manager at a credit union, a matter arises concerning Fire and Smoke Control in Pyrophoric Gases Storage during regulatory inspection. The a transaction monitoring alert suggests that a facility maintenance contract for a specialized laboratory tenant has lapsed, leading to a review of their silane storage protocols. Upon reviewing the life safety plans for the gas room, you observe that the gas cabinets are connected to the general building exhaust. To comply with safety standards for pyrophoric materials, which requirement must the dedicated exhaust system for these cabinets satisfy?
Correct
Correct: For pyrophoric gases like silane, which ignite spontaneously in air, continuous mechanical exhaust ventilation is required to prevent any accumulation of leaked gas. The system must maintain a negative pressure within the gas cabinet or exhausted enclosure to ensure that any leakage is contained and safely moved to the exterior. Because the hazard is immediate and severe, an emergency or standby power source is necessary to ensure the ventilation remains functional during a power outage.
Incorrect: Shutting down the exhaust system upon smoke detection is incorrect because it would allow the pyrophoric gas to accumulate, leading to a fire or explosion within the building. Recirculating air is prohibited for hazardous gas storage because it fails to remove the hazard from the environment and can lead to dangerous concentrations. Relying on a 25 percent LEL threshold for activation is insufficient for pyrophoric gases, as they ignite upon contact with air regardless of concentration, necessitating constant, proactive ventilation.
Takeaway: Exhaust systems for pyrophoric gas storage must be dedicated, continuous, and backed by emergency power to ensure constant negative pressure and immediate removal of leaked gases.
Incorrect
Correct: For pyrophoric gases like silane, which ignite spontaneously in air, continuous mechanical exhaust ventilation is required to prevent any accumulation of leaked gas. The system must maintain a negative pressure within the gas cabinet or exhausted enclosure to ensure that any leakage is contained and safely moved to the exterior. Because the hazard is immediate and severe, an emergency or standby power source is necessary to ensure the ventilation remains functional during a power outage.
Incorrect: Shutting down the exhaust system upon smoke detection is incorrect because it would allow the pyrophoric gas to accumulate, leading to a fire or explosion within the building. Recirculating air is prohibited for hazardous gas storage because it fails to remove the hazard from the environment and can lead to dangerous concentrations. Relying on a 25 percent LEL threshold for activation is insufficient for pyrophoric gases, as they ignite upon contact with air regardless of concentration, necessitating constant, proactive ventilation.
Takeaway: Exhaust systems for pyrophoric gas storage must be dedicated, continuous, and backed by emergency power to ensure constant negative pressure and immediate removal of leaked gases.
-
Question 2 of 10
2. Question
Senior management at a mid-sized retail bank requests your input on Fire and Smoke Control in Water-Reactive Gases Storage as part of control testing. Their briefing note explains that the bank’s main infrastructure hub recently transitioned to using specialized water-reactive gases for its emergency power-cell cooling systems. During a 48-hour internal audit of the facility’s life safety systems, you observe that the storage room is located adjacent to the main server hall and is currently protected by the building’s standard automatic wet-pipe sprinkler system. Which of the following represents the most appropriate recommendation to mitigate the risks associated with fire and smoke management in this storage area?
Correct
Correct: For water-reactive materials, NFPA 400 and related fire codes emphasize the elimination of water as a suppression agent to prevent violent chemical reactions, hydrogen gas generation, or explosions. A dedicated mechanical exhaust system is essential to manage smoke and hazardous vapors independently of the building’s main air handling units, ensuring that reactive products are not distributed to other zones.
Incorrect: Pre-action systems still utilize water, which is the primary hazard in a water-reactive gas scenario. HEPA filters in general HVAC systems do not address the chemical reactivity of the smoke or the potential for the HVAC system to spread hazardous vapors. Passive gravity vents are often inadequate for the rapid and controlled removal of hazardous smoke required in high-risk chemical storage environments compared to dedicated mechanical exhaust.
Takeaway: Fire protection for water-reactive gases must focus on water exclusion and independent, specialized ventilation to prevent catastrophic chemical reactions and cross-contamination.
Incorrect
Correct: For water-reactive materials, NFPA 400 and related fire codes emphasize the elimination of water as a suppression agent to prevent violent chemical reactions, hydrogen gas generation, or explosions. A dedicated mechanical exhaust system is essential to manage smoke and hazardous vapors independently of the building’s main air handling units, ensuring that reactive products are not distributed to other zones.
Incorrect: Pre-action systems still utilize water, which is the primary hazard in a water-reactive gas scenario. HEPA filters in general HVAC systems do not address the chemical reactivity of the smoke or the potential for the HVAC system to spread hazardous vapors. Passive gravity vents are often inadequate for the rapid and controlled removal of hazardous smoke required in high-risk chemical storage environments compared to dedicated mechanical exhaust.
Takeaway: Fire protection for water-reactive gases must focus on water exclusion and independent, specialized ventilation to prevent catastrophic chemical reactions and cross-contamination.
-
Question 3 of 10
3. Question
How should Fire and Smoke Control in Flammable Solids Storage be correctly understood for NFPA Certified Fire Plan Examiner? When reviewing the design for a facility storing high-hazard flammable solids, which design principle most effectively addresses the risk of rapid fire growth and the accumulation of toxic, buoyant gases to maintain tenable conditions for egress and firefighting operations?
Correct
Correct: In high-hazard storage environments, the use of smoke and heat vents combined with draft curtains is a recognized strategy to manage the smoke layer. Draft curtains (or draft stops) divide the ceiling area into smaller reservoirs, which traps the hot smoke and gases, allowing the vents within that reservoir to exhaust the products of combustion more efficiently. This prevents the smoke from spreading horizontally across the entire facility (mushrooming) and helps prevent the operation of sprinklers far from the fire seat, which preserves hydraulic pressure for the heads directly over the fire.
Incorrect: The use of high-expansion foam is a suppression strategy, not a smoke control strategy, and does not replace the requirement for venting combustion products. Pressurizing stairwells is a life safety tactic for egress paths but does not address the fire dynamics or smoke movement within the storage area itself. Relying on fire resistance ratings and oxygen depletion is incorrect because many flammable solids can burn in low-oxygen environments or react violently if the heat is not vented, and structural containment alone does not manage the buoyancy and movement of toxic smoke during the early stages of a fire.
Takeaway: Effective smoke control in flammable solids storage relies on the coordination of draft curtains and vents to compartmentalize and exhaust heat and smoke while protecting the integrity of the suppression system.
Incorrect
Correct: In high-hazard storage environments, the use of smoke and heat vents combined with draft curtains is a recognized strategy to manage the smoke layer. Draft curtains (or draft stops) divide the ceiling area into smaller reservoirs, which traps the hot smoke and gases, allowing the vents within that reservoir to exhaust the products of combustion more efficiently. This prevents the smoke from spreading horizontally across the entire facility (mushrooming) and helps prevent the operation of sprinklers far from the fire seat, which preserves hydraulic pressure for the heads directly over the fire.
Incorrect: The use of high-expansion foam is a suppression strategy, not a smoke control strategy, and does not replace the requirement for venting combustion products. Pressurizing stairwells is a life safety tactic for egress paths but does not address the fire dynamics or smoke movement within the storage area itself. Relying on fire resistance ratings and oxygen depletion is incorrect because many flammable solids can burn in low-oxygen environments or react violently if the heat is not vented, and structural containment alone does not manage the buoyancy and movement of toxic smoke during the early stages of a fire.
Takeaway: Effective smoke control in flammable solids storage relies on the coordination of draft curtains and vents to compartmentalize and exhaust heat and smoke while protecting the integrity of the suppression system.
-
Question 4 of 10
4. Question
The portfolio manager at a fintech lender is tasked with addressing Fire and Smoke Control in Blasting Agents Storage during onboarding. After reviewing a policy exception request, the key concern is that a proposed industrial warehouse utilizes a common HVAC and smoke management system across both the general storage area and the specialized blasting agent magazine. During the plan review for this facility, which design characteristic is most critical to ensure that a fire in the general storage area does not lead to the thermal decomposition or initiation of the blasting agents?
Correct
Correct: Blasting agents, such as ammonium nitrate mixtures, are sensitive to heat and can undergo thermal decomposition or detonation if exposed to high temperatures. A critical fire protection principle for these materials is isolation. Using a shared ventilation or smoke control system allows hot gases and smoke from a fire elsewhere in the building to enter the storage magazine, potentially raising the temperature of the agents to dangerous levels. Dedicated, independent ventilation ensures that the thermal energy from an external fire is not transferred to the hazardous materials through the air handling system.
Incorrect: While sprinklers are effective for ordinary combustibles, they may not prevent the thermal decomposition of blasting agents if the ambient temperature in the room rises due to smoke migration; furthermore, manual firefighting is generally discouraged once blasting agents are threatened due to the risk of explosion. Smoke purging for visibility is a secondary concern compared to heat isolation. Chemical films on containers are insufficient to protect against the sustained ambient heat rise that occurs in a shared ventilation scenario.
Takeaway: To prevent the accidental initiation of blasting agents, storage facilities must prioritize the total thermal and physical isolation of the storage area, particularly regarding shared air handling and smoke control systems.
Incorrect
Correct: Blasting agents, such as ammonium nitrate mixtures, are sensitive to heat and can undergo thermal decomposition or detonation if exposed to high temperatures. A critical fire protection principle for these materials is isolation. Using a shared ventilation or smoke control system allows hot gases and smoke from a fire elsewhere in the building to enter the storage magazine, potentially raising the temperature of the agents to dangerous levels. Dedicated, independent ventilation ensures that the thermal energy from an external fire is not transferred to the hazardous materials through the air handling system.
Incorrect: While sprinklers are effective for ordinary combustibles, they may not prevent the thermal decomposition of blasting agents if the ambient temperature in the room rises due to smoke migration; furthermore, manual firefighting is generally discouraged once blasting agents are threatened due to the risk of explosion. Smoke purging for visibility is a secondary concern compared to heat isolation. Chemical films on containers are insufficient to protect against the sustained ambient heat rise that occurs in a shared ventilation scenario.
Takeaway: To prevent the accidental initiation of blasting agents, storage facilities must prioritize the total thermal and physical isolation of the storage area, particularly regarding shared air handling and smoke control systems.
-
Question 5 of 10
5. Question
Which practical consideration is most relevant when executing Fire and Smoke Control in Water-Reactive Liquids Storage? An industrial facility is designing a dedicated storage room for Class 3 water-reactive liquids. During the plan review, the fire plan examiner must evaluate the proposed smoke management and fire suppression strategy. Given the nature of these materials, which design feature is most critical to prevent an uncontrolled escalation of a fire event?
Correct
Correct: Class 3 water-reactive liquids react vigorously with water, often resulting in explosions or the release of flammable or toxic gases. Therefore, traditional water-based suppression systems are contraindicated. A specialized agent like dry chemical or a clean agent is necessary to suppress the fire without triggering a dangerous chemical reaction. Additionally, smoke control must account for the specific chemical nature of the byproducts, which may be more hazardous than standard organic smoke.
Incorrect: High-density ESFR and standard wet-pipe sprinkler systems are inappropriate because the application of water to water-reactive liquids can cause a violent exothermic reaction, potentially leading to a pressure vessel failure or an explosion. Natural ventilation is generally insufficient for hazardous material storage rooms where active mechanical exhaust is required to manage the concentration of toxic or flammable vapors and to ensure the safety of emergency responders.
Takeaway: Fire protection for water-reactive liquids must utilize non-aqueous suppression agents and specialized mechanical ventilation to prevent violent chemical reactions and manage hazardous byproducts.
Incorrect
Correct: Class 3 water-reactive liquids react vigorously with water, often resulting in explosions or the release of flammable or toxic gases. Therefore, traditional water-based suppression systems are contraindicated. A specialized agent like dry chemical or a clean agent is necessary to suppress the fire without triggering a dangerous chemical reaction. Additionally, smoke control must account for the specific chemical nature of the byproducts, which may be more hazardous than standard organic smoke.
Incorrect: High-density ESFR and standard wet-pipe sprinkler systems are inappropriate because the application of water to water-reactive liquids can cause a violent exothermic reaction, potentially leading to a pressure vessel failure or an explosion. Natural ventilation is generally insufficient for hazardous material storage rooms where active mechanical exhaust is required to manage the concentration of toxic or flammable vapors and to ensure the safety of emergency responders.
Takeaway: Fire protection for water-reactive liquids must utilize non-aqueous suppression agents and specialized mechanical ventilation to prevent violent chemical reactions and manage hazardous byproducts.
-
Question 6 of 10
6. Question
How do different methodologies for Fire and Smoke Control in Oxidizing Liquids Storage compare in terms of effectiveness? A fire plan examiner is reviewing the life safety and property protection features for a facility storing significant quantities of Class 3 oxidizing liquids. The facility design must address the fact that these materials can undergo rapid decomposition and release oxygen, which intensifies fire growth and produces corrosive smoke. When evaluating the smoke management strategy, which of the following approaches is most effective for protecting the building structure and occupants from the specific decomposition products of oxidizing liquids?
Correct
Correct: Oxidizing liquids are unique because they provide their own oxygen to support combustion and can release highly corrosive or toxic vapors during decomposition. Mechanical exhaust ventilation is the most effective methodology because it provides a controlled means of removing these hazardous products and maintaining negative pressure. This prevents the migration of corrosive smoke to other parts of the facility, which is a primary concern for both life safety and the protection of the building’s structural integrity and sensitive equipment.
Incorrect: Natural-draft venting is often insufficient for the rapid and unpredictable smoke production rates associated with chemical decomposition and lacks the positive control needed to prevent migration. Carbon dioxide and other gaseous suppression agents are generally ineffective against oxidizers because the oxidizer itself provides the oxygen for the reaction, meaning displacement of ambient air does not stop the fire. High-expansion foam, while useful for some hazards, can be chemically degraded by strong oxidizers and is not a recognized or reliable method for primary smoke control or vapor containment in these scenarios.
Takeaway: Smoke control for oxidizing liquids must prioritize the mechanical removal and containment of corrosive decomposition products, as these materials provide their own oxygen and produce highly reactive smoke.
Incorrect
Correct: Oxidizing liquids are unique because they provide their own oxygen to support combustion and can release highly corrosive or toxic vapors during decomposition. Mechanical exhaust ventilation is the most effective methodology because it provides a controlled means of removing these hazardous products and maintaining negative pressure. This prevents the migration of corrosive smoke to other parts of the facility, which is a primary concern for both life safety and the protection of the building’s structural integrity and sensitive equipment.
Incorrect: Natural-draft venting is often insufficient for the rapid and unpredictable smoke production rates associated with chemical decomposition and lacks the positive control needed to prevent migration. Carbon dioxide and other gaseous suppression agents are generally ineffective against oxidizers because the oxidizer itself provides the oxygen for the reaction, meaning displacement of ambient air does not stop the fire. High-expansion foam, while useful for some hazards, can be chemically degraded by strong oxidizers and is not a recognized or reliable method for primary smoke control or vapor containment in these scenarios.
Takeaway: Smoke control for oxidizing liquids must prioritize the mechanical removal and containment of corrosive decomposition products, as these materials provide their own oxygen and produce highly reactive smoke.
-
Question 7 of 10
7. Question
In your capacity as risk manager at a fund administrator, you are handling Fire and Smoke Control in Water-Reactive Gases Storage during market conduct. A colleague forwards you a policy exception request showing that a newly acquired industrial storage unit utilizes a standard automatic wet-pipe sprinkler system in a zone designated for high-pressure cylinders of water-reactive toxic gases. The facility manager argues that the high ceiling height of 30 feet and the presence of smoke heat vents (SHV) mitigate the risk of a violent reaction by dispersing heat and moisture quickly. Based on fire protection principles for special hazards, which of the following is the most critical deficiency in this fire and smoke control strategy?
Correct
Correct: For water-reactive materials, the primary fire protection concern is the chemical incompatibility between the extinguishing agent (water) and the stored material. When water contacts water-reactive gases, it can cause a violent chemical reaction, generate significant heat, or produce flammable or toxic byproducts. Standard fire protection practice for these hazards involves using alternative suppression agents like dry chemicals or inert gases, or providing physical separation and moisture-free environments, rather than relying on water-based systems.
Incorrect: While it is true that smoke heat vents can delay sprinkler activation by venting heat (option b), this is a secondary design concern compared to the risk of a hazardous chemical reaction. Ceiling height limitations (option c) are a matter of hydraulic design and sprinkler selection but do not address the fundamental hazard of water reactivity. Environmental filtration (option d) is a post-incident or containment concern and does not address the immediate fire dynamics or the risk of the initial reaction caused by the sprinkler discharge.
Takeaway: The selection of fire suppression agents must be strictly compatible with the chemical properties of stored materials to prevent hazardous exothermic reactions or toxic releases.
Incorrect
Correct: For water-reactive materials, the primary fire protection concern is the chemical incompatibility between the extinguishing agent (water) and the stored material. When water contacts water-reactive gases, it can cause a violent chemical reaction, generate significant heat, or produce flammable or toxic byproducts. Standard fire protection practice for these hazards involves using alternative suppression agents like dry chemicals or inert gases, or providing physical separation and moisture-free environments, rather than relying on water-based systems.
Incorrect: While it is true that smoke heat vents can delay sprinkler activation by venting heat (option b), this is a secondary design concern compared to the risk of a hazardous chemical reaction. Ceiling height limitations (option c) are a matter of hydraulic design and sprinkler selection but do not address the fundamental hazard of water reactivity. Environmental filtration (option d) is a post-incident or containment concern and does not address the immediate fire dynamics or the risk of the initial reaction caused by the sprinkler discharge.
Takeaway: The selection of fire suppression agents must be strictly compatible with the chemical properties of stored materials to prevent hazardous exothermic reactions or toxic releases.
-
Question 8 of 10
8. Question
Which statement most accurately reflects Fire and Smoke Control in Pyrophoric Liquids Storage for NFPA Certified Fire Plan Examiner in practice? When reviewing the life safety and fire protection plans for a facility storing organometallic pyrophoric liquids, the examiner must assess the compatibility of the proposed systems with the unique hazards of materials that ignite spontaneously in air. Which of the following represents the most appropriate design consideration for these environments?
Correct
Correct: Pyrophoric liquids, such as certain organometallic compounds, ignite spontaneously upon exposure to air at temperatures of 130 degrees Fahrenheit or below. Because many of these substances react violently with water, traditional sprinkler systems may be inappropriate or dangerous. Therefore, the use of inert gas (like nitrogen or argon) to maintain an oxygen-deficient atmosphere or specialized dry chemical agents is critical. Furthermore, because these fires involve high energy and rapid growth, smoke control systems must be specifically designed to manage the extreme thermal radiation and the specific chemical nature of the smoke produced.
Incorrect: The use of standard water-based ESFR sprinklers is often contraindicated for pyrophoric liquids due to the risk of violent exothermic reactions or hydrogen gas generation upon contact with water. Relying on structural fire resistance alone is insufficient because it does not address the immediate life safety hazards of smoke and toxic gases. High-expansion foam, while effective for many flammable liquids, contains a high percentage of water and may be incompatible with many pyrophoric substances; additionally, natural ventilation is generally inadequate for the rapid and intense smoke production associated with pyrophoric combustion.
Takeaway: Fire and smoke control for pyrophoric liquids requires specialized suppression agents compatible with the chemical’s reactivity and smoke management systems capable of handling rapid-growth, high-intensity thermal events.
Incorrect
Correct: Pyrophoric liquids, such as certain organometallic compounds, ignite spontaneously upon exposure to air at temperatures of 130 degrees Fahrenheit or below. Because many of these substances react violently with water, traditional sprinkler systems may be inappropriate or dangerous. Therefore, the use of inert gas (like nitrogen or argon) to maintain an oxygen-deficient atmosphere or specialized dry chemical agents is critical. Furthermore, because these fires involve high energy and rapid growth, smoke control systems must be specifically designed to manage the extreme thermal radiation and the specific chemical nature of the smoke produced.
Incorrect: The use of standard water-based ESFR sprinklers is often contraindicated for pyrophoric liquids due to the risk of violent exothermic reactions or hydrogen gas generation upon contact with water. Relying on structural fire resistance alone is insufficient because it does not address the immediate life safety hazards of smoke and toxic gases. High-expansion foam, while effective for many flammable liquids, contains a high percentage of water and may be incompatible with many pyrophoric substances; additionally, natural ventilation is generally inadequate for the rapid and intense smoke production associated with pyrophoric combustion.
Takeaway: Fire and smoke control for pyrophoric liquids requires specialized suppression agents compatible with the chemical’s reactivity and smoke management systems capable of handling rapid-growth, high-intensity thermal events.
-
Question 9 of 10
9. Question
Which safeguard provides the strongest protection when dealing with Fire and Smoke Control in Flammable Liquids Storage? In an industrial facility storing significant quantities of Class I flammable liquids, the plan examiner must evaluate the effectiveness of the proposed life safety and property protection measures. The design includes various active and passive systems intended to mitigate the risks of vapor ignition and smoke migration to adjacent compartments.
Correct
Correct: The integration of mechanical ventilation, automatic dampers, and suppression systems ensures that flammable vapors are managed effectively to stay below the Lower Flammable Limit (LFL) during normal operations. By interlocking these systems with vapor detection, the facility can initiate a proactive response to leaks before ignition occurs, while fire-rated dampers prevent the migration of smoke and heat to other areas of the building, adhering to the principles of NFPA 30 and NFPA 92.
Incorrect: Gravity vents are often insufficient for heavy flammable vapors that tend to settle near the floor, making them less reliable than mechanical exhaust. Structural enhancements, while beneficial for containment, do not address the immediate life safety threat of smoke and fire spread. Manual overrides and portable equipment introduce significant risks of human error and delayed response times, which are unacceptable in high-hazard environments. Standard commercial HVAC systems, even with HEPA filtration, are not designed to handle the chemical nature or the intense volume of smoke produced by liquid fires.
Takeaway: Effective fire and smoke control in flammable liquid storage requires an integrated approach that combines continuous vapor management with automated detection and suppression to prevent ignition and contain smoke.
Incorrect
Correct: The integration of mechanical ventilation, automatic dampers, and suppression systems ensures that flammable vapors are managed effectively to stay below the Lower Flammable Limit (LFL) during normal operations. By interlocking these systems with vapor detection, the facility can initiate a proactive response to leaks before ignition occurs, while fire-rated dampers prevent the migration of smoke and heat to other areas of the building, adhering to the principles of NFPA 30 and NFPA 92.
Incorrect: Gravity vents are often insufficient for heavy flammable vapors that tend to settle near the floor, making them less reliable than mechanical exhaust. Structural enhancements, while beneficial for containment, do not address the immediate life safety threat of smoke and fire spread. Manual overrides and portable equipment introduce significant risks of human error and delayed response times, which are unacceptable in high-hazard environments. Standard commercial HVAC systems, even with HEPA filtration, are not designed to handle the chemical nature or the intense volume of smoke produced by liquid fires.
Takeaway: Effective fire and smoke control in flammable liquid storage requires an integrated approach that combines continuous vapor management with automated detection and suppression to prevent ignition and contain smoke.
-
Question 10 of 10
10. Question
A regulatory inspection at a fintech lender focuses on Fire and Smoke Control in Oxidizing Gases Storage in the context of complaints handling. The examiner notes that employees have expressed concerns regarding the storage of oxygen cylinders in a multi-purpose utility room that also contains paper records and plastic shipping materials. The examiner observes that the cylinders are not separated from these combustibles by the required 20-foot distance or a noncombustible barrier. Which fire science principle justifies the examiner’s insistence on immediate remediation to protect the building’s smoke control and egress systems?
Correct
Correct: Oxidizing gases, while not flammable themselves, provide a concentrated source of oxygen that significantly enhances the combustion process. This leads to a much higher heat release rate (HRR) and faster flame spread in surrounding combustible materials. In the context of fire and smoke control, this accelerated fire growth can produce smoke volumes that exceed the design capacity of the building’s smoke management systems and drastically reduce the time available for occupants to use egress routes before flashover occurs.
Incorrect: Oxidizing gases do not react with atmospheric nitrogen to create smoke; smoke is the result of the incomplete combustion of fuel. They do not create hyperbaric environments in standard storage rooms, nor do they interfere with the physical mechanism of heat-sensitive sprinkler heads. Furthermore, oxidizers do not cause the pyrolysis of polymers or the release of toxic gases at room temperature; they require an ignition source and a fuel to participate in a combustion reaction.
Takeaway: The primary hazard of oxidizing gases in storage is their ability to accelerate fire growth and smoke production by increasing the combustion rate of nearby materials.
Incorrect
Correct: Oxidizing gases, while not flammable themselves, provide a concentrated source of oxygen that significantly enhances the combustion process. This leads to a much higher heat release rate (HRR) and faster flame spread in surrounding combustible materials. In the context of fire and smoke control, this accelerated fire growth can produce smoke volumes that exceed the design capacity of the building’s smoke management systems and drastically reduce the time available for occupants to use egress routes before flashover occurs.
Incorrect: Oxidizing gases do not react with atmospheric nitrogen to create smoke; smoke is the result of the incomplete combustion of fuel. They do not create hyperbaric environments in standard storage rooms, nor do they interfere with the physical mechanism of heat-sensitive sprinkler heads. Furthermore, oxidizers do not cause the pyrolysis of polymers or the release of toxic gases at room temperature; they require an ignition source and a fuel to participate in a combustion reaction.
Takeaway: The primary hazard of oxidizing gases in storage is their ability to accelerate fire growth and smoke production by increasing the combustion rate of nearby materials.