Question 1 of 9
1. Question
The risk committee at an insurer is debating standards for Glazing performance (SHGC, U-value, VT) as part of internal audit remediation. The central issue is that several commercial assets in the portfolio have undergone unauthorized window film installations to reduce glare. During a 2023 portfolio review, it was noted that these modifications were not reflected in the thermal models used for energy performance forecasting. When conducting a NABERS Energy rating for an office building in a cooling-dominated climate, how should the assessor evaluate the impact of a high Solar Heat Gain Coefficient (SHGC) on the final rating outcome?
Correct
Correct: The Solar Heat Gain Coefficient (SHGC) measures the fraction of solar radiation admitted through a window. In cooling-dominated climates, which characterize much of the Australian commercial landscape, a high SHGC allows significant heat gain into the occupied space. This increases the thermal load on the HVAC system, leading to higher electricity consumption for cooling. Since NABERS Energy ratings are based on actual energy consumption data, this increased load results in a lower star rating.
Incorrect: The suggestion that high SHGC improves ratings via lighting is incorrect because the energy penalty from increased cooling loads usually far exceeds the savings from reduced artificial lighting. The claim that SHGC is neutral is false; while NABERS measures consumption, the envelope performance is a primary driver of that consumption. The idea that high SHGC is preferred in all climates is incorrect because in many Australian regions, the cooling load is the dominant energy driver, and high solar gain is detrimental to efficiency.
Takeaway: In the context of NABERS Energy ratings, glazing with a high SHGC increases cooling loads in warm climates, leading to higher energy use and a lower overall performance rating.
Incorrect
Correct: The Solar Heat Gain Coefficient (SHGC) measures the fraction of solar radiation admitted through a window. In cooling-dominated climates, which characterize much of the Australian commercial landscape, a high SHGC allows significant heat gain into the occupied space. This increases the thermal load on the HVAC system, leading to higher electricity consumption for cooling. Since NABERS Energy ratings are based on actual energy consumption data, this increased load results in a lower star rating.
Incorrect: The suggestion that high SHGC improves ratings via lighting is incorrect because the energy penalty from increased cooling loads usually far exceeds the savings from reduced artificial lighting. The claim that SHGC is neutral is false; while NABERS measures consumption, the envelope performance is a primary driver of that consumption. The idea that high SHGC is preferred in all climates is incorrect because in many Australian regions, the cooling load is the dominant energy driver, and high solar gain is detrimental to efficiency.
Takeaway: In the context of NABERS Energy ratings, glazing with a high SHGC increases cooling loads in warm climates, leading to higher energy use and a lower overall performance rating.
-
Question 2 of 9
2. Question
Working as the MLRO for a fund administrator, you encounter a situation involving Apartment Buildings: during client suitability. Upon examining a transaction monitoring alert, you discover that a property management client is attempting to finalize a NABERS Energy rating for a high-rise residential complex where a central gas-fired hot water system serves both the residential apartments and an unmetered ground-floor retail space. The client has requested that the assessor exclude 15% of the gas consumption based on a third-party consultant’s estimate of the retail usage to ensure the building meets its sustainability performance targets. According to the NABERS Rules for Apartment Buildings, how must this energy consumption be handled?
Correct
Correct: According to the NABERS Rules, specifically regarding the treatment of shared services, any energy source that serves both the rated premises (the apartment building) and a non-rated area (the retail space) must be fully included in the rating unless it is accurately sub-metered. NABERS does not permit the use of estimates, even from qualified engineers, to subtract energy loads from a rating. This ensures the integrity and comparability of the rating system by relying solely on verifiable, metered data.
Incorrect: Excluding energy based on engineering estimates is prohibited under NABERS protocols to prevent data manipulation and ensure accuracy. Pro-rating energy based on floor area (NLA) is not a recognized method for excluding shared services in the absence of meters. Excluding the system entirely would result in an under-reporting of the residential energy use, which violates the fundamental principle that all energy used by the rated premises must be accounted for.
Takeaway: In NABERS ratings, shared service energy consumption cannot be excluded or estimated without compliant sub-metering, regardless of the impact on the final star rating.
Incorrect
Correct: According to the NABERS Rules, specifically regarding the treatment of shared services, any energy source that serves both the rated premises (the apartment building) and a non-rated area (the retail space) must be fully included in the rating unless it is accurately sub-metered. NABERS does not permit the use of estimates, even from qualified engineers, to subtract energy loads from a rating. This ensures the integrity and comparability of the rating system by relying solely on verifiable, metered data.
Incorrect: Excluding energy based on engineering estimates is prohibited under NABERS protocols to prevent data manipulation and ensure accuracy. Pro-rating energy based on floor area (NLA) is not a recognized method for excluding shared services in the absence of meters. Excluding the system entirely would result in an under-reporting of the residential energy use, which violates the fundamental principle that all energy used by the rated premises must be accounted for.
Takeaway: In NABERS ratings, shared service energy consumption cannot be excluded or estimated without compliant sub-metering, regardless of the impact on the final star rating.
-
Question 3 of 9
3. Question
How can the inherent risks in NABERS Indoor Environment for Apartment Buildings be most effectively addressed? An Accredited Assessor is tasked with conducting a rating for a 20-story residential complex that utilizes a combination of natural ventilation and centralized mechanical systems. During the planning phase, the assessor identifies significant variability in the building’s orientation and the potential for localized acoustic disturbances from a nearby transit corridor.
Correct
Correct: The NABERS Indoor Environment (IE) for Apartment Buildings protocol requires that the assessment reflects the actual experience of occupants. To mitigate the risk of inaccurate or biased ratings, the assessor must follow a rigorous sampling methodology. This involves selecting apartments that represent the diversity of the building’s physical characteristics, such as height (which affects wind pressure and thermal stack effects), orientation (which affects solar gain), and location relative to noise sources (which affects acoustic comfort). Adhering to the specific spatial and temporal requirements in the NABERS Rules ensures the rating is valid and reliable.
Incorrect: Relying solely on building management system (BMS) or smart thermostat data is insufficient because these systems are often not calibrated to the precision required by NABERS IE protocols and may not capture all required parameters like acoustics or lighting. Selecting only shoulder seasons or closing windows during acoustic tests would manipulate the results and fail to capture the building’s true operational performance. Applying a standardized buffer to a single floor’s data is a violation of the measurement and verification (M&V) protocols, which require actual representative sampling rather than arbitrary mathematical adjustments.
Takeaway: Effective risk management in NABERS IE ratings requires a representative sampling strategy that captures the building’s diverse environmental conditions and strictly adheres to the spatial requirements of the Rules.
Incorrect
Correct: The NABERS Indoor Environment (IE) for Apartment Buildings protocol requires that the assessment reflects the actual experience of occupants. To mitigate the risk of inaccurate or biased ratings, the assessor must follow a rigorous sampling methodology. This involves selecting apartments that represent the diversity of the building’s physical characteristics, such as height (which affects wind pressure and thermal stack effects), orientation (which affects solar gain), and location relative to noise sources (which affects acoustic comfort). Adhering to the specific spatial and temporal requirements in the NABERS Rules ensures the rating is valid and reliable.
Incorrect: Relying solely on building management system (BMS) or smart thermostat data is insufficient because these systems are often not calibrated to the precision required by NABERS IE protocols and may not capture all required parameters like acoustics or lighting. Selecting only shoulder seasons or closing windows during acoustic tests would manipulate the results and fail to capture the building’s true operational performance. Applying a standardized buffer to a single floor’s data is a violation of the measurement and verification (M&V) protocols, which require actual representative sampling rather than arbitrary mathematical adjustments.
Takeaway: Effective risk management in NABERS IE ratings requires a representative sampling strategy that captures the building’s diverse environmental conditions and strictly adheres to the spatial requirements of the Rules.
-
Question 4 of 9
4. Question
Your team is drafting a policy on Application of simulation for performance prediction and optimisation as part of whistleblowing for a credit union. A key unresolved point is the risk assessment of using energy simulation models to forecast future NABERS Energy ratings for the credit union’s head office following a major HVAC system upgrade. During the internal audit of the project’s feasibility study, the audit team noted that the simulation predicted a 5.5-star outcome, but the current operational data suggests significant variability. What is the most critical risk an internal auditor should identify regarding the use of these simulations for predicting a NABERS rating?
Correct
Correct: The most significant risk is the performance gap between theoretical models and real-world outcomes. NABERS ratings are based on actual, measured energy consumption over a continuous 12-month period. Simulations often rely on standardized profiles for occupancy, setpoints, and equipment usage which may not reflect the actual, often less efficient, way a building is operated or maintained by the credit union staff and tenants.
Incorrect: While weather files are important, NABERS ratings are based on actual utility data and the rating is normalized for the actual weather experienced during that period, making the simulation’s weather file a secondary predictive risk rather than a rating compliance risk. Using simulation data to replace missing meter readings is strictly prohibited by NABERS rules, but the primary risk in a prediction context is the accuracy of the forecast itself. Finally, NABERS does not require a certified simulation professional for a standard rating submission, as ratings are based on bills, not models.
Takeaway: Internal auditors must recognize that energy simulations are predictive tools with inherent assumptions that often fail to capture the complexities of actual 12-month building operations required for a NABERS rating.
Incorrect
Correct: The most significant risk is the performance gap between theoretical models and real-world outcomes. NABERS ratings are based on actual, measured energy consumption over a continuous 12-month period. Simulations often rely on standardized profiles for occupancy, setpoints, and equipment usage which may not reflect the actual, often less efficient, way a building is operated or maintained by the credit union staff and tenants.
Incorrect: While weather files are important, NABERS ratings are based on actual utility data and the rating is normalized for the actual weather experienced during that period, making the simulation’s weather file a secondary predictive risk rather than a rating compliance risk. Using simulation data to replace missing meter readings is strictly prohibited by NABERS rules, but the primary risk in a prediction context is the accuracy of the forecast itself. Finally, NABERS does not require a certified simulation professional for a standard rating submission, as ratings are based on bills, not models.
Takeaway: Internal auditors must recognize that energy simulations are predictive tools with inherent assumptions that often fail to capture the complexities of actual 12-month building operations required for a NABERS rating.
-
Question 5 of 9
5. Question
Following an alert related to On-site measurement techniques for energy, water, and waste, what is the proper response when an assessor discovers during a site walkthrough that a significant cooling tower water meter has been bypassed for maintenance and is not recording consumption?
Correct
Correct: According to NABERS Rules and M&V protocols, all energy and water consumption must be accounted for. If a meter is bypassed or fails, it creates a data gap. The assessor must first attempt to find alternative verifiable data (such as a secondary meter). If no such data exists, the assessor must follow the specific ‘Missing Data’ hierarchy in the NABERS Rules, which generally requires a conservative estimate (often the maximum potential consumption) to ensure the building does not receive a higher rating due to missing usage data.
Incorrect: Option B is incorrect because simple averaging is not the standard procedure for missing data under NABERS; it lacks the required conservatism to prevent rating manipulation. Option C is incorrect because excluding consumption would result in an artificially low water usage figure, leading to an inaccurate and unfairly high star rating. Option D is incorrect because a contractor’s informal estimate does not meet the rigorous evidence and verification standards required for primary data under the NABERS Rules.
Takeaway: When on-site measurement data is missing or compromised, assessors must apply the conservative estimation protocols defined in the NABERS Rules to maintain the integrity of the rating.
Incorrect
Correct: According to NABERS Rules and M&V protocols, all energy and water consumption must be accounted for. If a meter is bypassed or fails, it creates a data gap. The assessor must first attempt to find alternative verifiable data (such as a secondary meter). If no such data exists, the assessor must follow the specific ‘Missing Data’ hierarchy in the NABERS Rules, which generally requires a conservative estimate (often the maximum potential consumption) to ensure the building does not receive a higher rating due to missing usage data.
Incorrect: Option B is incorrect because simple averaging is not the standard procedure for missing data under NABERS; it lacks the required conservatism to prevent rating manipulation. Option C is incorrect because excluding consumption would result in an artificially low water usage figure, leading to an inaccurate and unfairly high star rating. Option D is incorrect because a contractor’s informal estimate does not meet the rigorous evidence and verification standards required for primary data under the NABERS Rules.
Takeaway: When on-site measurement data is missing or compromised, assessors must apply the conservative estimation protocols defined in the NABERS Rules to maintain the integrity of the rating.
-
Question 6 of 9
6. Question
Following an on-site examination at a broker-dealer, regulators raised concerns about Data visualisation techniques in the context of outsourcing. Their preliminary finding is that the firm’s reliance on a third-party service provider to manage utility data for its NABERS Energy rating led to missed opportunities for identifying data integrity issues. During a 12-month review period, the outsourced reports presented data primarily in aggregate tables, which failed to highlight a significant HVAC energy spike during a three-week low-occupancy period. To ensure compliance with NABERS data validation requirements and professional audit standards, which visualization technique should the internal auditor recommend to best identify such anomalies?
Correct
Correct: Time-series line charts are the most effective tool for identifying temporal anomalies in energy data. By overlaying consumption with occupancy schedules and temperature, an auditor can visually detect when energy use does not align with expected operational patterns (e.g., high HVAC use when the building is empty), which is a core requirement for data validation under NABERS protocols.
Incorrect: Static bar charts comparing annual data are too high-level to detect short-term spikes or anomalies occurring within a specific three-week window. Pie charts show the composition of energy use but lack the temporal dimension necessary to correlate usage with specific events or occupancy changes. Scatter plots correlating floor area with water consumption do not address the specific issue of HVAC energy spikes relative to time and occupancy.
Takeaway: Effective data visualization for NABERS assessments must utilize temporal analysis to correlate energy consumption with operational variables like occupancy and weather to ensure data integrity.
Incorrect
Correct: Time-series line charts are the most effective tool for identifying temporal anomalies in energy data. By overlaying consumption with occupancy schedules and temperature, an auditor can visually detect when energy use does not align with expected operational patterns (e.g., high HVAC use when the building is empty), which is a core requirement for data validation under NABERS protocols.
Incorrect: Static bar charts comparing annual data are too high-level to detect short-term spikes or anomalies occurring within a specific three-week window. Pie charts show the composition of energy use but lack the temporal dimension necessary to correlate usage with specific events or occupancy changes. Scatter plots correlating floor area with water consumption do not address the specific issue of HVAC energy spikes relative to time and occupancy.
Takeaway: Effective data visualization for NABERS assessments must utilize temporal analysis to correlate energy consumption with operational variables like occupancy and weather to ensure data integrity.
-
Question 7 of 9
7. Question
A new business initiative at a private bank requires guidance on NABERS Indoor Environment for Hotels as part of control testing. The proposal raises questions about the sampling methodology used for thermal comfort and air quality measurements. During a 10-day monitoring period, an internal auditor notices that the assessor has selected a specific subset of guest rooms for sensor placement. To comply with the NABERS Indoor Environment Rules, how should these guest rooms be selected to ensure the rating is valid?
Correct
Correct: According to the NABERS Indoor Environment Rules for Hotels, the sampling of guest rooms must be representative of the building’s overall configuration. This includes selecting rooms with different orientations (e.g., North vs. South) and at different heights (e.g., low, mid, and high floors) because these factors significantly influence thermal loads and air distribution. This ensures the resulting IE score reflects the experience of a typical guest across the entire facility.
Incorrect: Selecting rooms based on occupancy rates is not a requirement for IE sensor placement, as the focus is on the physical environment’s performance rather than guest behavior. Restricting samples to a single vertical stack would create a biased sample that fails to account for different orientations and HVAC zones. While testing the furthest rooms might seem logical for a stress test, NABERS requires a representative average of the building’s performance, not a ‘worst-case scenario’ focused exclusively on the most distant rooms.
Takeaway: A valid NABERS IE rating for hotels requires a representative sampling of guest rooms across various orientations and floors to accurately assess the building’s environmental performance.
Incorrect
Correct: According to the NABERS Indoor Environment Rules for Hotels, the sampling of guest rooms must be representative of the building’s overall configuration. This includes selecting rooms with different orientations (e.g., North vs. South) and at different heights (e.g., low, mid, and high floors) because these factors significantly influence thermal loads and air distribution. This ensures the resulting IE score reflects the experience of a typical guest across the entire facility.
Incorrect: Selecting rooms based on occupancy rates is not a requirement for IE sensor placement, as the focus is on the physical environment’s performance rather than guest behavior. Restricting samples to a single vertical stack would create a biased sample that fails to account for different orientations and HVAC zones. While testing the furthest rooms might seem logical for a stress test, NABERS requires a representative average of the building’s performance, not a ‘worst-case scenario’ focused exclusively on the most distant rooms.
Takeaway: A valid NABERS IE rating for hotels requires a representative sampling of guest rooms across various orientations and floors to accurately assess the building’s environmental performance.
-
Question 8 of 9
8. Question
As the compliance officer at a fintech lender, you are reviewing Ethical Conduct and Professional Practice during gifts and entertainment when a policy exception request arrives on your desk. It reveals that an external NABERS Accredited Assessor, currently engaged to perform a formal rating for the firm’s headquarters, has been offered a premium hospitality package for an upcoming sporting event by the building’s facility manager. The assessor is concerned about the implications for their professional standing. According to the NABERS Code of Practice and professional standards, how should this situation be managed to ensure the validity of the rating?
Correct
Correct: NABERS Accredited Assessors are bound by a strict Code of Practice that mandates independence and objectivity. Accepting gifts, hospitality, or entertainment from a client or a party associated with the building being rated (such as a facility manager) creates a significant conflict of interest. To maintain the integrity of the rating and comply with ethical standards, the assessor must remain impartial and avoid any situation that could be perceived as compromising their professional judgment.
Incorrect: Providing a written declaration of impartiality does not remove the ethical breach or the perception of a conflict of interest created by accepting a gift. While peer review is a good quality control measure, it does not excuse the primary assessor from their individual ethical obligations under the NABERS program. Internal corporate gift registers and general industry networking standards do not override the specific, more stringent independence requirements set by the NABERS Administrator for accredited assessors.
Takeaway: Maintaining professional independence and avoiding even the perception of a conflict of interest is fundamental to the role of a NABERS Accredited Assessor.
Incorrect
Correct: NABERS Accredited Assessors are bound by a strict Code of Practice that mandates independence and objectivity. Accepting gifts, hospitality, or entertainment from a client or a party associated with the building being rated (such as a facility manager) creates a significant conflict of interest. To maintain the integrity of the rating and comply with ethical standards, the assessor must remain impartial and avoid any situation that could be perceived as compromising their professional judgment.
Incorrect: Providing a written declaration of impartiality does not remove the ethical breach or the perception of a conflict of interest created by accepting a gift. While peer review is a good quality control measure, it does not excuse the primary assessor from their individual ethical obligations under the NABERS program. Internal corporate gift registers and general industry networking standards do not override the specific, more stringent independence requirements set by the NABERS Administrator for accredited assessors.
Takeaway: Maintaining professional independence and avoiding even the perception of a conflict of interest is fundamental to the role of a NABERS Accredited Assessor.
-
Question 9 of 9
9. Question
During a periodic assessment of Correct application of the tools for data input and calculation as part of incident response at a payment services provider, auditors observed that the facility management team had entered aggregate utility data into the NABERS Rate tool for a mixed-use building. The audit revealed that for a period of 60 days, the sub-metering for the non-rated data centre component was non-functional. To maintain the rating schedule, the assessor utilized a calculation method not explicitly defined in the NABERS Rules to estimate the data centre’s consumption and subtract it from the total building load. Which action should the auditor recommend to ensure the integrity of the NABERS rating calculation?
Correct
Correct: According to NABERS Rules, all data entered into the rating tool must be verifiable and follow the hierarchy of evidence. If a sub-meter fails and a non-rated load cannot be accurately measured, that energy cannot be subtracted from the total building load. The most conservative approach required by the Rules is to include that energy in the rated coverage, effectively penalizing the rating for the lack of data, unless a specific, approved estimation methodology (such as those found in the NABERS Ruling for missing data) is applicable.
Incorrect: Using historical averages from the preceding 12 months is a common error and is not permitted under NABERS Rules as a standard substitute for metered data without specific authorization. Flagging a period as excluded is not a standard function of the NABERS Rate tool for energy data gaps; the rating must cover a continuous 12-month period. Relying solely on a utility provider’s letter for total load does not solve the problem of accurately deducting the non-rated sub-metered loads, which is the core requirement for a mixed-use rating.
Takeaway: In the event of sub-meter failure, assessors must adhere strictly to the NABERS Rules for missing data, which typically requires including unmetered loads in the rated consumption to maintain a conservative and verifiable rating.
Incorrect
Correct: According to NABERS Rules, all data entered into the rating tool must be verifiable and follow the hierarchy of evidence. If a sub-meter fails and a non-rated load cannot be accurately measured, that energy cannot be subtracted from the total building load. The most conservative approach required by the Rules is to include that energy in the rated coverage, effectively penalizing the rating for the lack of data, unless a specific, approved estimation methodology (such as those found in the NABERS Ruling for missing data) is applicable.
Incorrect: Using historical averages from the preceding 12 months is a common error and is not permitted under NABERS Rules as a standard substitute for metered data without specific authorization. Flagging a period as excluded is not a standard function of the NABERS Rate tool for energy data gaps; the rating must cover a continuous 12-month period. Relying solely on a utility provider’s letter for total load does not solve the problem of accurately deducting the non-rated sub-metered loads, which is the core requirement for a mixed-use rating.
Takeaway: In the event of sub-meter failure, assessors must adhere strictly to the NABERS Rules for missing data, which typically requires including unmetered loads in the rated consumption to maintain a conservative and verifiable rating.