Question 1 of 7
1. Question
The board of directors at an investment firm has asked for a recommendation regarding Advanced Legal and Contractual Disputes as part of incident response. The background paper states that a multi-unit Passive House development is facing litigation due to systemic interstitial condensation and mold growth within the building envelope 24 months after completion. The firm must determine the most robust method for establishing professional due diligence and mitigating liability related to the design and execution of the air barrier and vapor control layers. Which risk assessment and mitigation strategy should the firm prioritize to defend against future contractual disputes regarding building envelope integrity?
Correct
Correct: In the context of Passive House design and legal disputes, the most effective defense against professional negligence is the ability to prove that the design was executed correctly through a rigorous quality assurance (QA) process. Multi-stage blower door testing (at the ‘bones’ stage and final completion) and photographic evidence of air barrier continuity provide an empirical audit trail. This demonstrates that the designer and contractor met the required performance standards and followed the necessary moisture management protocols, which is critical in defending against claims of latent defects or design failure.
Incorrect: Relying on vapor-retardant paints is insufficient for Passive House standards as it does not address air leakage, which is the primary driver of moisture transport. Transferring risk to a mechanical contractor via a performance bond for energy consumption does not address the underlying structural damage caused by moisture in the envelope. Eliminating the air barrier by using non-hygroscopic insulation is a fundamental misunderstanding of building science; air barriers are required to prevent convective heat loss and moisture transport regardless of the insulation type used.
Takeaway: Rigorous, documented verification of airtightness and envelope continuity is the primary legal safeguard against professional negligence claims in high-performance building projects.
Incorrect
Correct: In the context of Passive House design and legal disputes, the most effective defense against professional negligence is the ability to prove that the design was executed correctly through a rigorous quality assurance (QA) process. Multi-stage blower door testing (at the ‘bones’ stage and final completion) and photographic evidence of air barrier continuity provide an empirical audit trail. This demonstrates that the designer and contractor met the required performance standards and followed the necessary moisture management protocols, which is critical in defending against claims of latent defects or design failure.
Incorrect: Relying on vapor-retardant paints is insufficient for Passive House standards as it does not address air leakage, which is the primary driver of moisture transport. Transferring risk to a mechanical contractor via a performance bond for energy consumption does not address the underlying structural damage caused by moisture in the envelope. Eliminating the air barrier by using non-hygroscopic insulation is a fundamental misunderstanding of building science; air barriers are required to prevent convective heat loss and moisture transport regardless of the insulation type used.
Takeaway: Rigorous, documented verification of airtightness and envelope continuity is the primary legal safeguard against professional negligence claims in high-performance building projects.
-
Question 2 of 7
2. Question
The monitoring system at a private bank has flagged an anomaly related to Energy Recovery Ventilation (ERV) during change management. Investigation reveals that the enthalpy exchange core was replaced with a standard sensible-only heat recovery core during a scheduled 48-hour maintenance window. The internal audit team is assessing the impact on the building’s climate control strategy and Passive House compliance. What is the most significant technical consequence of this specific component change when the building is operating in a humid summer climate?
Correct
Correct: An Energy Recovery Ventilator (ERV) is distinguished from a Heat Recovery Ventilator (HRV) by its ability to transfer both sensible heat and latent heat (moisture). In a humid climate, the ERV’s enthalpy core removes moisture from the incoming fresh air and transfers it to the exhaust air stream. By replacing it with a sensible-only core, the system loses its dehumidification capability, forcing the cooling system to work harder to remove the moisture (latent load), which increases energy use and risks indoor comfort issues.
Incorrect: Option b is incorrect because while sensible efficiency is important, Passive House standards do not set a maximum limit that would cause overheating simply by being ‘too efficient’ in this context; the issue is the loss of moisture control. Option c is incorrect because the fan RPM is typically controlled by the building management system based on flow sensors, not the presence of a desiccant layer. Option d is incorrect because the airtightness of a building (measured by blower door tests) is a function of the building envelope’s air barrier, not the internal configuration of the heat exchanger core.
Takeaway: The primary functional difference between ERV and HRV systems is the ERV’s ability to manage latent heat (moisture) transfer, which is critical for energy efficiency and humidity control in humid climates.
Incorrect
Correct: An Energy Recovery Ventilator (ERV) is distinguished from a Heat Recovery Ventilator (HRV) by its ability to transfer both sensible heat and latent heat (moisture). In a humid climate, the ERV’s enthalpy core removes moisture from the incoming fresh air and transfers it to the exhaust air stream. By replacing it with a sensible-only core, the system loses its dehumidification capability, forcing the cooling system to work harder to remove the moisture (latent load), which increases energy use and risks indoor comfort issues.
Incorrect: Option b is incorrect because while sensible efficiency is important, Passive House standards do not set a maximum limit that would cause overheating simply by being ‘too efficient’ in this context; the issue is the loss of moisture control. Option c is incorrect because the fan RPM is typically controlled by the building management system based on flow sensors, not the presence of a desiccant layer. Option d is incorrect because the airtightness of a building (measured by blower door tests) is a function of the building envelope’s air barrier, not the internal configuration of the heat exchanger core.
Takeaway: The primary functional difference between ERV and HRV systems is the ERV’s ability to manage latent heat (moisture) transfer, which is critical for energy efficiency and humidity control in humid climates.
-
Question 3 of 7
3. Question
During a routine supervisory engagement with an investment firm, the authority asks about Breach of Contract Claims in the context of data protection. They observe that the firm is currently litigating a performance failure in their new Passive House certified headquarters, where the building envelope failed to meet the 0.6 ACH50 airtightness threshold. The firm claims a breach of contract because the contractor’s failure to ensure air barrier continuity has led to unexpected interstitial condensation. In the context of building science and moisture management, which principle explains why the breach of airtightness specifications is more likely to cause structural moisture damage than a failure in the vapor diffusion strategy?
Correct
Correct: In building science, convective moisture transport (air leakage) can move hundreds of times more water into a building assembly than vapor diffusion. In a Passive House design, maintaining a continuous air barrier is critical because even small gaps can allow large amounts of warm, moist air to reach cold surfaces within the assembly, leading to condensation and mold. This makes the breach of airtightness a much more severe risk to structural integrity than issues related to vapor diffusion alone.
Incorrect: Vapor diffusion is a relatively slow process compared to the rapid transport of moisture via air currents. Air barriers are intended to stop air movement, not bulk liquid water (which is the role of the weather-resistive barrier). While the temperature gradient (and thus the dew point location) is influenced by insulation, the actual presence of moisture that leads to condensation is heavily dependent on air leakage through the envelope.
Takeaway: Convective moisture transport via air leakage is a far more significant threat to building durability and performance than vapor diffusion in high-performance envelopes.
Incorrect
Correct: In building science, convective moisture transport (air leakage) can move hundreds of times more water into a building assembly than vapor diffusion. In a Passive House design, maintaining a continuous air barrier is critical because even small gaps can allow large amounts of warm, moist air to reach cold surfaces within the assembly, leading to condensation and mold. This makes the breach of airtightness a much more severe risk to structural integrity than issues related to vapor diffusion alone.
Incorrect: Vapor diffusion is a relatively slow process compared to the rapid transport of moisture via air currents. Air barriers are intended to stop air movement, not bulk liquid water (which is the role of the weather-resistive barrier). While the temperature gradient (and thus the dew point location) is influenced by insulation, the actual presence of moisture that leads to condensation is heavily dependent on air leakage through the envelope.
Takeaway: Convective moisture transport via air leakage is a far more significant threat to building durability and performance than vapor diffusion in high-performance envelopes.
-
Question 4 of 7
4. Question
The compliance framework at a broker-dealer is being updated to address Indoor Air Quality (IAQ) as part of regulatory inspection. A challenge arises because the facility’s existing mechanical system is unable to maintain the required 30 m3/h of fresh air per person without significant thermal discomfort and energy penalties. To align with Passive House principles for a healthy work environment, the internal audit team recommends a system overhaul. Which approach best ensures both high IAQ and energy efficiency in this airtight building envelope?
Correct
Correct: In Passive House design, high indoor air quality is achieved through a balanced mechanical ventilation system. This system provides a continuous supply of fresh, filtered outdoor air while simultaneously extracting stale, moist air. The use of a heat recovery ventilator (HRV) or energy recovery ventilator (ERV) ensures that the thermal energy from the exhaust air is transferred to the incoming fresh air, maintaining comfort and efficiency. Fine dust filtration (typically F7 or ePM1 50%) is required on the supply side to protect the heat exchanger and ensure the health of occupants.
Incorrect: Increasing infiltration through the building envelope is contrary to the Passive House requirement for airtightness and leads to uncontrolled heat loss and potential moisture damage. Extract-only systems with trickle vents create drafts, allow noise pollution, and do not provide heat recovery, making them energy-inefficient. Recirculating air systems with UV or carbon scrubbing may treat certain pollutants but do not address the buildup of CO2 or provide the necessary fresh air exchange required by Passive House hygiene standards.
Takeaway: Passive House IAQ is fundamentally based on balanced mechanical ventilation with heat recovery and high-level filtration to ensure constant fresh air without energy loss.
Incorrect
Correct: In Passive House design, high indoor air quality is achieved through a balanced mechanical ventilation system. This system provides a continuous supply of fresh, filtered outdoor air while simultaneously extracting stale, moist air. The use of a heat recovery ventilator (HRV) or energy recovery ventilator (ERV) ensures that the thermal energy from the exhaust air is transferred to the incoming fresh air, maintaining comfort and efficiency. Fine dust filtration (typically F7 or ePM1 50%) is required on the supply side to protect the heat exchanger and ensure the health of occupants.
Incorrect: Increasing infiltration through the building envelope is contrary to the Passive House requirement for airtightness and leads to uncontrolled heat loss and potential moisture damage. Extract-only systems with trickle vents create drafts, allow noise pollution, and do not provide heat recovery, making them energy-inefficient. Recirculating air systems with UV or carbon scrubbing may treat certain pollutants but do not address the buildup of CO2 or provide the necessary fresh air exchange required by Passive House hygiene standards.
Takeaway: Passive House IAQ is fundamentally based on balanced mechanical ventilation with heat recovery and high-level filtration to ensure constant fresh air without energy loss.
-
Question 5 of 7
5. Question
A regulatory guidance update affects how an audit firm must handle Humidity Control in the context of sanctions screening. The new requirement implies that technical auditors must evaluate the risk of low indoor air quality and structural degradation caused by improper moisture balance in certified high-performance buildings. During an audit of a Passive House project in a cold, dry climate, the auditor identifies that the building is equipped with a standard Heat Recovery Ventilator (HRV). Given that the building has a very low occupancy density and minimal internal moisture gains, there is a significant risk that indoor relative humidity will fall below 30% during the winter. Which design modification would best mitigate this risk while adhering to Passive House energy efficiency standards?
Correct
Correct: In cold climates, the primary method for maintaining indoor humidity in a Passive House without active humidification is the use of an ERV. Unlike an HRV, which only transfers sensible heat, an ERV uses a specialized core to transfer moisture (latent heat) from the outgoing exhaust air to the incoming dry supply air, helping to maintain comfortable indoor humidity levels and reducing the energy demand associated with active humidification.
Incorrect: Recirculating indoor air is generally discouraged in Passive House design as it can compromise the fresh air requirement and does not address the net loss of moisture through the ventilation exhaust. Reducing the effectiveness of the vapor retarder is dangerous as it encourages interstitial condensation and does not effectively humidify the interior. Increasing ventilation rates at night is counterproductive in winter because, although outdoor relative humidity might be high, the absolute moisture content of cold air is extremely low; heating that air will result in even lower indoor relative humidity.
Takeaway: In dry climates, an Energy Recovery Ventilator (ERV) is the preferred solution for maintaining indoor humidity levels by recovering latent heat from the exhaust air.
Incorrect
Correct: In cold climates, the primary method for maintaining indoor humidity in a Passive House without active humidification is the use of an ERV. Unlike an HRV, which only transfers sensible heat, an ERV uses a specialized core to transfer moisture (latent heat) from the outgoing exhaust air to the incoming dry supply air, helping to maintain comfortable indoor humidity levels and reducing the energy demand associated with active humidification.
Incorrect: Recirculating indoor air is generally discouraged in Passive House design as it can compromise the fresh air requirement and does not address the net loss of moisture through the ventilation exhaust. Reducing the effectiveness of the vapor retarder is dangerous as it encourages interstitial condensation and does not effectively humidify the interior. Increasing ventilation rates at night is counterproductive in winter because, although outdoor relative humidity might be high, the absolute moisture content of cold air is extremely low; heating that air will result in even lower indoor relative humidity.
Takeaway: In dry climates, an Energy Recovery Ventilator (ERV) is the preferred solution for maintaining indoor humidity levels by recovering latent heat from the exhaust air.
-
Question 6 of 7
6. Question
The supervisory authority has issued an inquiry to a fintech lender concerning Comfort Criteria in the context of regulatory inspection. The letter states that an internal audit of the lender’s green-certified real estate portfolio found that several Passive House buildings are experiencing high rates of tenant turnover due to thermal discomfort. During a winter inspection, it was observed that while the air temperature was a constant 20°C, the interior surface temperature of the windows was only 14°C. Which of the following best describes the comfort criterion that has been breached in this scenario?
Correct
Correct: In Passive House design, thermal comfort is heavily dependent on the operative temperature, which is the average of the air temperature and the mean radiant temperature of surrounding surfaces. To ensure comfort and prevent the sensation of being ‘chilled’ by cold surfaces, the interior surface temperature of any building component (including windows) should not be more than 4.2 Kelvin (4.2°C) lower than the indoor air temperature. In this scenario, the difference is 6 Kelvin (20°C – 14°C), which exceeds the comfort threshold and leads to radiant temperature asymmetry.
Incorrect: Option b refers to draft risk, which is a comfort criterion related to air movement rather than surface temperature. Option c refers to stratification, which deals with temperature gradients from floor to ceiling rather than the radiant effect of cold walls or windows. Option d refers to the ‘hygiene criterion,’ which is indeed a Passive House requirement to prevent mold, but the scenario specifically highlights occupant discomfort and feeling cold, which is a thermal comfort issue related to radiant heat exchange.
Takeaway: Passive House comfort requires that the interior surface temperatures of all envelope components remain within 4.2K of the indoor air temperature to maintain a stable operative temperature and avoid radiant asymmetry.
Incorrect
Correct: In Passive House design, thermal comfort is heavily dependent on the operative temperature, which is the average of the air temperature and the mean radiant temperature of surrounding surfaces. To ensure comfort and prevent the sensation of being ‘chilled’ by cold surfaces, the interior surface temperature of any building component (including windows) should not be more than 4.2 Kelvin (4.2°C) lower than the indoor air temperature. In this scenario, the difference is 6 Kelvin (20°C – 14°C), which exceeds the comfort threshold and leads to radiant temperature asymmetry.
Incorrect: Option b refers to draft risk, which is a comfort criterion related to air movement rather than surface temperature. Option c refers to stratification, which deals with temperature gradients from floor to ceiling rather than the radiant effect of cold walls or windows. Option d refers to the ‘hygiene criterion,’ which is indeed a Passive House requirement to prevent mold, but the scenario specifically highlights occupant discomfort and feeling cold, which is a thermal comfort issue related to radiant heat exchange.
Takeaway: Passive House comfort requires that the interior surface temperatures of all envelope components remain within 4.2K of the indoor air temperature to maintain a stable operative temperature and avoid radiant asymmetry.
-
Question 7 of 7
7. Question
How should Interpretation Conflicts be implemented in practice? During a professional audit of a Passive House project’s building envelope, an internal reviewer identifies a conflict between the airtightness layer’s continuity as specified in the construction details and the actual installation of structural steel penetrations.
Correct
Correct: In high-performance building audits, technical performance and risk mitigation are paramount. When a conflict is identified that threatens the air barrier’s continuity, the auditor must ensure that the design is corrected to meet the mandatory Passive House airtightness standards, as this is essential for both energy performance and structural durability.
Incorrect
Correct: In high-performance building audits, technical performance and risk mitigation are paramount. When a conflict is identified that threatens the air barrier’s continuity, the auditor must ensure that the design is corrected to meet the mandatory Passive House airtightness standards, as this is essential for both energy performance and structural durability.